Your security camera can be an ignition source

In a classified area, mounting a camera is a regulated act — BC's OHS Regulation names electrical equipment that is not permitted for hazardous locations as an ignition source.

Guard Nation Security7 min read

Someone is standing on a ladder in your plant with a hammer drill and a camera bracket. They are a competent installer. They have done a thousand of these. Nobody has told them that the room they are drilling into is a classified area, because nobody told you either — it is on a drawing in a binder somewhere, and the binder is not on the ladder.

That is the whole problem in one sentence. In most BC industrial buildings, the security system gets installed by people who were hired to solve a security problem and were never handed the information that turns their work into a regulated act.

The rule that applies is not a security rule

It sits in the Occupational Health and Safety Regulation, in the part about chemical and biological substances. Section 5.27 is titled "Ignition sources," and subsection (1) says:

When a combustible liquid normally used as fuel, a flammable gas or a flammable liquid is handled, used or stored, all sources of ignition must be eliminated or adequately controlled.

Then subsection (2) tells you what counts as a source of ignition:

For the purposes of subsection (1) sources of ignition include open flame, spark-producing mechanical equipment, welding and cutting processes, smoking, static discharge and any electrical equipment or installation that is not permitted under the B.C. Electrical Code for use in hazardous locations.

Read that list again and notice the company your camera is keeping. Open flame. Welding. Smoking. Static discharge. And then, at the end of the same sentence, electrical equipment or installation that is not permitted for use in hazardous locations.

The regulation does not distinguish between a heater, a light fixture, a motor and a security camera. It says electrical equipment or installation. A dome camera is electrical equipment. So is a card reader, a request-to-exit sensor, an electric strike, a wireless access point, a junction box, and the conduit and connectors that tie them together. If it is in the classified area and it is not permitted for use there, it is on the same list as an open flame.

"Installation" is doing a lot of work in that sentence

This is the part that catches people who did buy the right equipment.

The regulation names equipment or installation. Suitability is not only a property of the box you bought — it is a property of how the box was fitted, sealed, bonded, and wired, and of every penetration made to get the cable there. So an ordinary gland, an ordinary backbox, an unsealed conduit run out of the classified area, or an extra hole drilled on site to get a cable in at a better angle are all inside the rule's reach, even where the device itself is correctly rated. What specifically makes an installation permitted or not comes from the B.C. Electrical Code read against your area classification — not from a list in an article, including this one.

Cameras invite exactly this. They get repositioned. Somebody adds a second camera off the same run six months later. A contractor swaps a failed unit for whatever was on the van that day, because it looks the same and it is only a camera. Each of those is a change to an installation in a classified area, made by someone who did not know that is what they were doing.

Someone has to be able to tell you where the boundaries are.

Where this actually lives in BC

If you operate a sawmill, a planer mill, a pellet or wood-products plant, a grain or feed handling facility, a paint or coating shop, a fuel depot, a cardlock, a bulk plant, a marina fuel dock, a solvent storage room, a battery charging room, a paint booth, or a plant with a chemical storage building, you almost certainly have areas someone has classified — and areas someone has assumed are not classified without checking.

One point of precision, because it matters: section 5.27 is written around a combustible liquid normally used as fuel, a flammable gas or a flammable liquid. Those are the words. Plenty of BC sites — mills, grain and feed handling, wood-products plants — carry hazards that are not liquids or gases at all, and other provisions govern those. This article does not attempt to tell you which rules apply to a dust hazard. It tells you what the ignition-source rule says about the fuel, solvent, and flammable-gas areas that almost every one of those same sites also has: the fuel island, the solvent room, the paint or coating area, the propane storage, the battery charging room.

The gaps show up in predictable places. The boundary of a classified area is a three-dimensional volume, not a room, and it does not stop at the wall the drawing was drawn on. Camera positions are chosen for sightlines, and the best sightline is usually high, central, and directly over the thing that makes the area hazardous in the first place. Nobody thinks of a plastic housing on a bracket as an electrical installation. And the person picking the mounting point is standing on a ladder, not reading a classification drawing.

Classified means somebody has to have decided

Hazardous locations in BC are classified — an area gets assessed, given a designation, and the equipment permitted inside it follows from that designation. We are deliberately not naming schemes or ratings here, because the correct designation for your building is not something to take from an article. It comes from your area classification, and equipment approved for it carries its approval markings.

What matters for the decision you are making this week is simpler:

Someone has to be able to tell you where the boundaries are. If nobody at your site can produce a classification drawing or point at the boundary on a plan, that is the first finding, and it is bigger than the camera.

The equipment has to be approved for the classification your area actually has. Not for hazardous locations in general. There is no general.

The installation has to match. Sealing, glanding, enclosure integrity, wiring method, and every penetration. This is where the installation, not the device, decides the answer.

Somebody has to own the drawings afterward. An as-built that shows what was installed where, so the next contractor — the one replacing a failed camera in three years — is not standing on the ladder with the same missing information.

Who carries this

Not the installer alone. The obligations in Part 5 sit with the employer — and your security contractor is an employer too, carrying its own Part 5 duties for its own workers. Section 5.27 adds a further line on top of that for multi-employer sites; it coordinates the duties, it does not move the contractor's onto you. Subsection (3) says:

If the work involves more than one employer, the prime contractor or, if there is no prime contractor, the owner must ensure that sources of ignition resulting from the work of one employer are eliminated or adequately controlled in any work area where a combustible liquid normally used as fuel, a flammable gas or a flammable liquid is handled, used or stored by any other employer.

Read plainly, that means if you bring a security contractor into a plant where another employer is handling flammable product, the duty to control the ignition sources their work creates lands on the prime contractor, or on you as owner if there is no prime contractor. You cannot subcontract that to whoever is holding the drill. A signed quote is not a transfer of obligation.

Which is why "we assumed the installer knew" is not a position. Most security installers are genuinely good at security. Very few have been given a classification drawing on the way in, and almost none will ask for one, because in the hundreds of buildings they have wired, no one has ever mentioned it.

What to do before the next install

Ask the classification question in writing before anyone quotes the job, not after they have mobilized. Mark the classified areas on the drawing you give bidders and require them to state which devices land inside those boundaries. Require the equipment approval markings in the submittal, before purchase, not as a sticker discovered at commissioning. Treat a like-for-like camera swap inside a classified area as a change to an electrical installation, not as maintenance. And walk your existing system with someone who reads the boundaries, because the devices already on your walls were installed under the same assumptions.

None of this is exotic. It is the ordinary discipline your electrical trades already apply in those rooms. The gap is that security equipment arrives through a different door, on a different purchase order, from a vendor nobody thought to hand the drawings to.

If your site handles fuel, solvent, or flammable gas and you are unsure whether the devices already mounted there are appropriate for the areas they are in, that is worth resolving before it is discovered by an inspection — or by something worse.

Written by the Guard Nation Security team — from the sites we install, monitor, guard and investigate across British Columbia, and have since 2015.
General information, not legal or code advice · bylaws and enforcement differ by municipality, and your authority having jurisdiction has the final say.
Sources & the full caution

Sources

  • Occupational Health and Safety Regulation (B.C. Reg. 296/97), Part 5 — Chemical and Biological Substances, section 5.27 "Ignition sources" — https://www.worksafebc.com/en/law-policy/occupational-health-safety/searchable-ohs-regulation/ohs-regulation/part-05-chemical-and-biological-substances

Building and fire codes, municipal bylaws, and how they are enforced differ from one site to the next, and the authority having jurisdiction (AHJ) for your building has the final say — confirm current requirements with your AHJ and municipality before you act on anything here, and for legal decisions, with your lawyer.